focused on disposable surgical medical instruments
Home >> Products >> Medical Stapler
gastrointestinal surgery
Leave A MessageLive ChatThe Disposable Circular Stapler is a crucial medical device designed for surgical procedures. It is engineered to create a secure and efficient anastomosis (connection) between two tubular structures within the body, such as in gastrointestinal surgeries.
This stapler comes with several outstanding features. First, its disposable nature ensures maximum sterility and eliminates the risk of cross - contamination that could occur with reusable devices. It is pre - sterilized and ready - to - use, saving valuable time in the operating room. Second, the circular design enables a uniform and precise staple placement around the circumference of the tissue, resulting in a reliable seal and promoting better tissue healing.
1.Indicator window shows clearly and precisely for the thickness of tissue.
2.Reasonable staples density to reduce hemorrhage after operation.
3.Imported titanium wire to offer better strength and degree of stretch.
4.One step forming anvil to ensure the staples formed completely.
5.Bigger ratio between the outside and cutting diameters avoids anastomotic strictures.
6.Set minimum anastomotic gap to avoid tissue damage because of over pressure.
7.Ergonomic design,powerful and comfortable hand-feeling when using.
Apply to end to end-end to side,side to side anastomosis in esophagealgastricintestinal etc clinical operation.
It is mainly used for end-to-end, end-to-side and side to side anastomosis of digestive tract inreconstruction of
esophagus, stomach and intestine.
Severe mucosal edema;
The product can not be used on the tissue with the pressing thickness less than 1 mm. Hemostasis was ensured because thestaples could not be clamped sufficiently;The product cannot be used for tissues that cannot be easily pressed to 2mm thickness, Because the tissue is too thick, whenthe buttress seat is closed with the kissing component,
It is easy to be pressed, resulting in poor healing or stenosis of anastomotic stoma;When the component diameter is much larger than the inner diameter of the lumen, the product can not be used. it maycause tissue stretching or thinning, resulting in anastomotic leakage or stenosis;This product can not be used when there is not enough tissue to allow normal turnover and it is difficult to nail theanastomosis nail firmly.
Size
| L | Tolerance | D (outer diameterof nail bin) | Tolerance | D1 (Outer diameterof circular knife) | Tolerance | H | Tolerance
|
H-CS21 | 450 | ± 10 | 21 | ± 1 | 13 | ± 2 | 4.5 | ± 0.3 |
H-CS24 | 24 | 15 | 4.5 | |||||
H-CS26 | 26 | 17 | 4.8 | |||||
H-CS29 | 29 | 20 | 4.8 | |||||
H-CS32 | 32 | 22 | 4.8 | |||||
H-CS34 | 34 | 23 | 5.0 |
to contact us please use the following form to submit your enquiry,we will contact you as soon as possible